Abstract:
The non-intrusive in-situ efficiency estimation of induction machines (IMs) in real industrial environment is given due consideration and its possibilities are thoroughly investigated. The non-intrusiveness refers to measurement of electrical input voltages and currents at IM terminals only. This thesis develops the techniques for estimating the
efficiency of IM in a non-intrusive manner for balanced/unbalanced power supplies. Also, energy auditing case studies of two industrial plants is undertaken to reduce
consumption of electrical power and enhance savings. Overall work has been completed in three sections.
First section is the study of numerous methods of efficiency estimation of IM and different standards applied so far. In this section, the mathematical modeling of IM is
done in D-Q reference frame. Efficiency calculation of IM is done in stationary reference
frame. The efficiency estimation of in-situ IM is accomplished through the development
of low cost non-intrusive air-gap torque method by doing modifications to original airgap torque method based on air-gap torque equations employing line-to-line voltages and
two phase currents with sufficient accuracy and least intrusion level. Speed estimation of
IM rotor is accomplished by model reference adaptive mechanism which utilizes rotor
flux error vector as tuning signal for speed estimation for IM drives in the speed
adaptation mechanism. Efficiency estimation is performed for both balanced and unbalanced conditions.
In the second section, population based algorithm i.e. cuckoo search algorithm (CSA) is proposed for efficiency estimation of in-situ IM which is capable of dealing with
balanced/unbalanced voltages. The proposed technique is non-intrusive in nature and needs least measurements like two line voltages and currents along with nameplate data
of IM. Also, gravitational search based algorithm (GSA) is proposed for efficiency estimation of in-service IMs which handles unbalanced/unbalanced voltages and gives
better results than CSA. These proposed techniques don’t alter any operating condition of IM.
In the third section analysis for energy auditing performed for two industrial plants i.e. Jindal Steel Plant (JSP) and Sohna Woolen Mill (SWM) to reduce their energy consumption is presented. This task is accomplished by analyzing the replacement of IMs
giving poor efficiencies by energy-efficient IMs of suitable ratings. In JSP, rescheduling of loads on power transformers is done to reduce the losses and burden on insulation of
over-loaded transformer. This enhances energy savings as well. Also, power factor improvement is suggested for JSP. During the process of energy auditing, the need of device for efficiency estimation of IM for any loading condition is felt since lot of time is
consumed in measurements of electrical input quantities. Conventional methods of efficiency estimation need de-coupling of IM from drive. Therefore, a low cost nonintrusive
handheld device is fabricated for evaluating IM efficiency. This device has PIC 18F4520 micro-controller which is programmed as per non-intrusive air-gap torque
method. This handheld device is implemented for efficiency estimation of IM in
balanced/unbalanced voltages.